Energy & utilities, side by side.
26 devices in 5 groups, each group the devices that do the same job, with the specs from the catalog. Each catalog number opens that device’s page.
Power and current
| Device | Measures | Range | Accuracy | Mount | Rating | Power |
|---|---|---|---|---|---|---|
| No. 13 12-channel electrical sub-meter | Current, voltage, kW, kVAR, kVA, kWh, kVAh, frequency and power factor | 12 channels; clamps to 600 A; voltage inputs rated 230 VAC, three-phase plus neutral | ±1% | DIN rail or wall in the panel | 5 to 60 °C operating | DC supply |
| No. 14 250 A smart current sensor | Current and amp-hours on one conductor | 250 A split-core; ±1% above 5 A, ±3% at 5 A and below | Not listed | Clamp on the conductor; radio outside the panel | IP30, indoor; −20 to 70 °C operating | Self-powered; no battery |
| No. 15 3-phase current meter, 1000 A | Current per phase; amp-hours | 3 × 1000 A split-core; ±1% | Not listed | Clamps on the main feeder; transceiver outside the gear | IP30, indoor; −20 to 70 °C operating | Self-powered (energy harvesting) or DC |
| No. 69 Self-powered power monitor | Voltage, current, power factor and energy (kWh and kVAh) | 85–277 VAC per phase | 2% (manufacturer rating) | Not listed | −40 to 85 °C | Self-powered from the monitored circuit |
| No. 71 Smart wall receptacle | Energy use and temperature | Not listed | ±1% (energy monitoring) | Wall receptacle | Indoor, 0 to 50 °C | 100–120 VAC mains |
| No. 72 Portable smart socket | Voltage, current, power, power factor and energy | Not listed | Not listed | Plugs into a wall outlet | IP20, indoor, −20 to 60 °C | 100–250 VAC mains |
Meter pulse readers
| Device | Reads | Inputs | Mount | Rating | Power |
|---|---|---|---|---|---|
| No. 16 Pulse counter | Not listed | Pulse / S0 | Beside the meter | IP67; −30 to 70 °C | Battery, about 5 years |
| No. 66 Two-input meter pulse reader | Pulses from water, gas, electric and heat meters | 2 pulse inputs: dry contact, reed, S0 or open collector | DIN rail, wall or pole | IP68; −25 to 70 °C | Battery, about 15 years in a typical configuration (manufacturer rating) |
| No. 67 Three-input pulse counter | Pulse outputs from electricity, gas, water and heat meters | 3 pulse inputs (S0 or dry contact) | Not listed | IP40 | Battery (lithium), about 3 years (manufacturer rating) |
| No. 68 Pulse and status counter | S0 meter pulses and contact open/closed status | 3 inputs, each set to pulse count or change of state | Not listed | IP40 | Battery (lithium), about 3 years (manufacturer rating) |
Pressure, flow and air velocity
| Device | Measures | Range | Accuracy | Connection | Mount | Rating | Power |
|---|---|---|---|---|---|---|---|
| No. 17 Air & liquid line pressure | Gauge pressure, air or liquid | Not listed | ±0.2% full scale | ¼-inch NPT | Not listed | −20 to 60 °C operating | Battery, about 5 years |
| No. 18 Differential pressure, air & gas | Differential pressure and temperature, air or gas | Not listed | ±0.2% of span | ⅛-inch NPT female, two ports | Not listed | IP66, outdoor | Battery |
| No. 19 Water flow meter, DN25 | Flow rate and total volume | 2–100 L/min on DN25 | ±5% | Not listed | In-line; G 1-inch thread (parallel pipe thread, not NPT) | Outdoor; −40 to 85 °C operating | Battery, about 5 years |
| No. 65 Duct air velocity sensor | Air velocity (thermal anemometer) | 0 to 40 m/s | Not listed | Not listed | Probe inserted into a duct or air handler | IP40, indoor | Battery (lithium), about 3 years (manufacturer rating) |
Modbus bridges and converters
| Device | Reads | Inputs | Radio | Mount | Rating | Power |
|---|---|---|---|---|---|---|
| No. 20 Modbus bridge | Modbus RTU over RS485 | Not listed | Not listed | Wall or desktop beside the controller | IP30, indoor; −20 to 60 °C | DC |
| No. 56 Modbus converter, 5–50 V DC | Modbus RTU registers, up to 32 per transmission (manufacturer rating) | 1 RS-485 serial port | LoRaWAN | Indoor | Not listed | 5–50 V DC |
| No. 57 Battery Modbus converter | Modbus RTU registers and serial sensor data | RS-485, UART, I2C, 1-Wire and digital input | LoRaWAN Class A | Outdoor | IP67; −40 to 65 °C | Lithium battery |
| No. 61 Two-way Modbus converter | Modbus RTU registers; sends commands for control | 1 RS-485 serial port | LoRaWAN Class C (always listening) | Not listed | Indoor; −40 to 65 °C | 7–24 V DC |
| No. 62 Plant-room Modbus bridge | Modbus RTU registers | RS-485 serial, 2 channels | LoRaWAN | Indoor, plant room or meter room | Not listed | 12–24 V DC |
Data loggers and input nodes
| Device | Inputs | Radio | Mount | Rating | Power |
|---|---|---|---|---|---|
| No. 58 Cellular data logger | Analog current and voltage, digital, pulse, SDI-12, RS-485, RS-232, I2C and 1-Wire | 4G cellular | Outdoor | IP68, −30 to 60 °C | DC, battery or solar (lithium-polymer battery) |
| No. 59 Waterproof sensor node | Analog voltage, digital, I2C and 1-Wire | LoRaWAN Class A | Outdoor | IP68 or IP66, by version | Lithium battery |
| No. 60 LoRaWAN data logger | RS-485 (Modbus RTU), analog current and voltage, digital and pulse | LoRaWAN Class A | Outdoor | IP66, −40 to 85 °C | 12 V DC or lithium battery, about 10 years (manufacturer rating) |
| No. 63 SDI-12 probe converter | SDI-12 | LoRaWAN Class A | Outdoor, in the field | −40 to 85 °C | Lithium battery, about 5 years (manufacturer rating) |
| No. 64 Analog input sensor | Analog, 0–10 V or 0–20 mA | LoRaWAN (North America) | Not listed | Not listed | Battery (lithium), about 3 years (manufacturer rating) |
| No. 70 Environmental sensor data node | Analog or digital field sensors | LoRaWAN, North America | Not listed | Not listed | Not listed |
| No. 73 Multi-input sensor node | Analog, digital and industrial sensor inputs | LoRaWAN, North America | Not listed | Not listed | Not listed |
Specs from the Cognituv Connect catalog (October 2026). Where the catalog gives no value, the table says “Not listed”. Confirm site suitability, calibration and current product specifications before ordering. The product data sheet governs.
Energy & utilities in the catalog →Ask an engineer to compare for your site →
Not sure which sensors you need?
Start from the problem you want to see. The planner suggests a gateway and monitoring points for your facility, and a Cognituv engineer confirms them.
Prefer to talk? Call 1-888-580-8738