Rotating equipment & heat, side by side.

20 devices in 4 groups, each group the devices that do the same job, with the specs from the catalog. Each catalog number opens that device’s page.

Vibration

DeviceMeasuresRangeRadioMountRatingPower
No. 05 Vibration & temperature monitorVelocity RMS, acceleration RMS and peak, peak-to-peak displacement, kurtosis, crest factor, skewness, standard deviation; surface temperature±16 g; −20 to 80 °C operatingNot listedStud (screw or bolt) or adhesive on the bearing housingIP66Battery, about 2 years at 15-minute reporting
No. 06 Explosion-proof vibration monitorVibration (3-axis) and surface temperature±16 g; 5–1000 Hz band; 0 to 70 °C operatingNot listedMagnet or studIP65Battery, about 2 years
No. 53 Vibration switch sensorVibration present or absent (rolling-ball switch, 2-gang)Not listedLoRaWAN (North America)MagnetIP65; −20 to 55 °C operatingLithium battery, about 5 years (manufacturer rating)
No. 54 Accelerometer & surface temperature sensorVibration on three axes, surface temperature±16 g up to 1,000 Hz; temperature −40 to 120 °CLoRaWAN (North America)MagnetIP65Lithium battery, about 3.5 years (manufacturer rating)
No. 55 Wideband FFT vibration sensorVibration on three axes (FFT spectrum, peak acceleration), temperature±25 g; 2 to 10,000 Hz; temperature −40 to 80 °CLoRaWAN (North America)Screw, magnet or adhesiveIP67; −40 to 60 °C operatingLithium battery, about 4 years (manufacturer rating)

Temperature on equipment

DeviceMeasuresRangeMountRatingPower
No. 07 Infrared surface-temperature sensorSurface temperature by infrared; ambient temperature−40 to 1030 °C target; adjustable emissivityBracket, aimed at the surfaceIP67; node −20 to 50 °CBattery, about 8.5 years
No. 09 High-temperature probe, 500 °CTemperature, PT100 RTD−50 to 500 °C; ±0.5 °C to 170 °C, ±1.2 °C aboveProbe in the exhaust or on the line; transmitter on a wall, pole or DIN rail within the 1.5 m leadIP67; transmitter −30 to 70 °CBattery, about 10 years
No. 10 High-temperature probe, 800 °CTemperature, PT100 RTD−50 to 800 °C; ±0.5 °C to 170 °C, ±1 °C to 420 °C, ±2 °C abovePole, wall or DIN rail; 1.5 m probe leadIP67; transmitter −30 to 70 °CBattery, about 10 years
No. 11 Waterproof PT100 probe, 200 °CTemperature on two probesUp to 200 °C; ±0.5 °C (0–80 °C), Class AWall transmitter; 2 m probe leadsTransmitter −40 to 65 °CBattery
No. 12 Three-probe temperature nodeTemperature on three probes−55 to 125 °C; ±0.5 °C typical (±2 °C max)Wall or pole; 1.5 m probe leadsIP66Battery, about 5 years
No. 48 Two-channel thermocouple sensorTemperature at two points−40 to 375 °CMagnetIP50, indoor; node operates −20 to 55 °CLithium battery, about 4.8 years (manufacturer rating)

Motor and feeder current

DeviceMeasuresRangeAccuracyInputsMountRatingPower
No. 08 3-phase current meter, 500 ACurrent per phase, amp-hours, A/B/C balance3 × 500 A split-core±1%Not listedClamps on the feeder inside the MCC bucket; radio outsideIP30, indoor; −20 to 70 °CSelf-powered from the conductor; no battery
No. 44 Battery three-phase current meterCurrent on each of three phasesUp to 150 A per clamp±1% (1 to 150 A)3 split-core clamp-on CTsWall or magnetIP53; −20 to 55 °CBattery (lithium)
No. 45 Self-powered high-current sensorTrue-RMS current on one conductorUp to 300, 400, 1000, 1500 or 4000 A, by versionNot listed1 split-core clamp-on CTClamps around one conductor at the switchgear, panel or feeder−40 to 85 °CSelf-powered from the monitored line
No. 46 Feeder current & amp-hour sensor, 4000 ATrue-RMS current, minimum and maximum current and amp-hoursUp to 4000 ANot listed1 split-core clamp-on CTClamps around one conductor at the switchgear or main feeder−40 to 85 °CSelf-powered from the monitored line
No. 47 Smart current sensor, 100 ACurrent and amp-hours on one conductorUp to 100 A±1% above 5 A; ±3% at or below 5 A1 split-core clamp-on CTClamps onto a single live wireIP30 (indoor); −20 to 70 °CSelf-powered from the monitored wire, or DC

Strain, position and tilt

All 4Radio: LoRaWAN (North America)

DeviceMeasuresRangeAccuracyRatingPower
No. 49 Strain & load sensorStrain (elongation) and force−45 to +90 µm elongation (−30 to +60 N)Not listedIP67; −10 to 50 °C operatingBattery (alkaline)
No. 50 Linear position sensorLinear displacement0 to 100 mm stroke0.2%IP67; −20 to 50 °C operatingBattery (alkaline)
No. 51 Two-axis tilt sensorTilt on two axes, temperatureNot listed±0.3°−40 to 85 °C operatingLithium battery, about 5 years (manufacturer rating)
No. 52 Tilt & surface temperature sensorTilt on three axes, surface temperatureTilt ±90°; temperature −40 to 120 °CAngle ±3°; temperature ±3 °CIP65Lithium battery, about 4 years (manufacturer rating)

Specs from the Cognituv Connect catalog (October 2026). Where the catalog gives no value, the table says “Not listed”. Confirm site suitability, calibration and current product specifications before ordering. The product data sheet governs.

Rotating equipment & heat in the catalog →Ask an engineer to compare for your site →

Not sure which sensors you need?

Start from the problem you want to see. The planner suggests a gateway and monitoring points for your facility, and a Cognituv engineer confirms them.

Prefer to talk? Call 1-888-580-8738

Plan your system