Environment & water, side by side.

59 devices in 10 groups, each group the devices that do the same job, with the specs from the catalog. Each catalog number opens that device’s page.

Indoor air monitors with displays

All 6Mount: Wall

DeviceMeasuresRadioDisplayRatingPower
No. 29 Multi-parameter indoor air monitorCO₂, TVOC, PM2.5, PM10, temperature, humidity, barometric pressure, light and motionNot listedE-ink, traffic-light statusIP30, indoor; −20 to 60 °C operatingBattery, about 1 year (manufacturer rating), or DC
No. 139 Room comfort display with motionTemperature, humidity, light and motionLoRaWAN, North AmericaE-inkIP30, indoor; 0 to 45 °C operatingBattery or DC; battery about 1.5 years (manufacturer rating)
No. 140 Temperature & humidity displayTemperature and humidityLoRaWAN, North America2.13-inch e-inkIP30, indoor; −20 to 60 °C operatingBattery, about 7 years (manufacturer rating)
No. 141 CO₂ room sensorCO₂, temperature and humidityLoRaWAN, North AmericaE-ink or noneIP30, indoor; −20 to 60 °C operatingBattery, about 4.5 years with display or 5 years without (manufacturer rating)
No. 142 Seven-in-one room monitor with displayCO₂, TVOC, temperature, humidity, barometric pressure, light and motionLoRaWAN, North AmericaE-inkIP30, indoor; −20 to 60 °C operatingBattery or DC; battery about 3 years (manufacturer rating)
No. 143 Air quality monitor with formaldehyde or ozoneCO₂, PM2.5, PM10, TVOC, temperature, humidity, barometric pressure, light and motion, plus formaldehyde or ozoneLoRaWAN, North AmericaE-inkIP30, indoor; −20 to 60 °C operatingDC

CO₂ and room sensors

All 9Radio: LoRaWAN, North America

DeviceMeasuresMountRatingPower
No. 124 Room ambiance monitorCO₂, TVOC, temperature, humidity, barometric pressure, light and motionWallIndoor; −10 to 50 °C operatingBattery, about 1.4 years (manufacturer rating)
No. 125 Wide-range CO₂ sensorCO₂, temperature, humidity and barometric pressureWall−10 to 50 °C operatingBattery, about 5.1 years (manufacturer rating)
No. 126 Rugged CO₂ & climate sensorCO₂ (NDIR), temperature, humidity and barometric pressureWall, pole or DIN railIP65; −30 to 70 °C operatingBattery, about 10 years (manufacturer rating)
No. 127 Restroom odor sensorAmmonia (NH₃), hydrogen sulfide (H₂S), temperature and humidityWallIP30, indoor; −40 to 55 °C operatingBattery, about 3 years (manufacturer rating)
No. 128 Wall or desk CO₂ sensorCO₂, temperature and humidityWall or deskIP30, indoor; −20 to 50 °C operatingBattery
No. 129 Room comfort sensor with noise levelCO₂, TVOC, temperature, humidity, light, presence and noise levelWall or deskIP30, indoor; −20 to 50 °C operatingBattery or USB-C; battery about 3 years (manufacturer rating)
No. 130 CO₂ sensor, IP66CO₂ (NDIR)Wall or poleIP66, indoor; 0 to 50 °C operatingBattery, about 3 years (manufacturer rating)
No. 131 Wall-plate temperature & humidity sensorTemperature and humidityWallNot listedBattery, about 3 years (manufacturer rating)
No. 132 Sound level & TVOC room sensorSound level, TVOC, light, temperature, humidity and barometric pressureWallNot listedBattery or DC

Particulate and air quality stations

DeviceMeasuresRadioMountPower
No. 30 Particulate monitor, PM1 to PM10PM1, PM2.5, PM4, PM10; temperature; humidity; barometric pressureNot listedWall or poleBattery, about 8 years, or DC
No. 133 Multi-gas air quality stationPM1, PM2.5 and PM10; NO₂, O₃ and CO; temperature, humidity and barometric pressureLoRaWAN, North AmericaNot listedNot listed
No. 134 CO₂ & particle air quality stationCO₂, TVOC, PM1, PM2.5, PM4, PM10, temperature, humidity and barometric pressureLoRaWAN, North AmericaWall or ceilingBattery or DC
No. 135 Ultrafine particle air quality stationPM0.1, PM1, PM2.5, PM10, CO₂, TVOC, temperature, humidity and barometric pressureLoRaWAN, North AmericaWall or ceilingDC or PoE
No. 136 Indoor air station with optional gasesCO₂, TVOC, oxygen (O₂), PM1, PM2.5, PM4, PM10, light, temperature, humidity and barometric pressureLoRaWAN, North AmericaCeiling or wallNot listed
No. 137 Outdoor air station with optional gasesCO₂, TVOC, oxygen (O₂), PM1, PM2.5, PM4, PM10, temperature, humidity and barometric pressureLoRaWAN, North AmericaWall or poleAC or DC
No. 138 Outdoor air quality monitorParticulates, gases and weather conditions; sound on the standard and CO₂ versions; CO₂ or carbon monoxide (CO) by versionLoRaWAN, North AmericaNot listedNot listed

Sound level

DeviceMeasuresRangeRadioMountRatingPower
No. 31 Sound level sensorSound pressure level; Leq; Lmax30–120 dBA; A or C weightingNot listedWall or columnIndoorBattery
No. 148 Outdoor sound level sensorSound level (dB)Not listedLoRaWAN, North AmericaNot listedNot listedNot listed

Weather and outdoor conditions

DeviceMeasuresRangeAccuracyRadioRatingPower
No. 32 Weather station, 11 parametersWind speed and direction, precipitation, solar radiation, lightning, temperature, humidity, barometric pressureWind 0–30 m/s, 0–359°; air −50 to 60 °C; humidity 0–100% RH; pressure 50–110 kPa; solar 0–1750 W/m²; precipitation 0–196 mm/h; lightning 0–40 kmWind 0.3 m/s or 3%, ±5°; air ±0.6 °C; humidity ±3% RH; pressure ±0.1 kPa; solar ±5%; precipitation ±5%Not listedIP67Alkaline battery
No. 118 Shielded outdoor temperature & humidity sensorAir temperature and relative humidity−40 to 125 °C±0.1 °C (20 to 60 °C), ±0.2 °C (−40 to 90 °C); ±1.5 %RH (0 to 80 %), ±2 %RH (80 to 100 %)LoRaWAN (North America)IP67; node operates −20 to 50 °CAlkaline batteries, about 12.2 years (manufacturer rating)
No. 119 Weatherproof temperature & humidity sensorTemperature and relative humidity−40 to 80 °C±0.2 °C (0 to 90 °C); ±2 %RH (0 to 100 %RH)LoRaWAN (North America)IP66; operates −40 to 85 °CLithium battery, about 5 years (manufacturer rating)
No. 120 Field air temperature & humidity sensorAir temperature and relative humidity−40 to 85 °C±0.2 °C; ±1.8 %RHLoRaWAN (North America)IP66; operates −40 to 85 °CLithium battery, about 10 years (manufacturer rating)
No. 121 Wind & temperature sensorWind speed, wind direction and air temperatureWind 0 to 30 m/s and 0 to 359°; air −50 to 60 °CWind 0.3 m/s or 3% and ±5°; air ±0.6 °CLoRaWAN, North AmericaIP67; −20 to 50 °C operatingBattery (alkaline)
No. 150 Road surface & dew point sensorSurface temperature (infrared), air temperature, humidity and dew pointSurface, air and dew point −40 to 70 °C; humidity 0 to 100%Air ±0.4 °C; humidity ±3%; dew point ±1.0 °CLoRaWAN, North AmericaIP67; −20 to 50 °C operatingBattery (alkaline)
No. 151 Road surface temperature sensorSurface temperature (infrared), air temperature and humiditySurface −40 to 1030 °C (infrared target range); air −40 to 125 °C; humidity 0 to 100%Surface ±1.5% or ±1.5 °C; air ±0.1 °C (20 to 60 °C); humidity ±1.5% RHLoRaWAN, North AmericaIP67Battery (alkaline)

Light and UV-C

All 3Radio: LoRaWAN, North America

DeviceMeasures
No. 145 Outdoor light sensorLight level (lux)
No. 146 Light intensity sensorLight intensity
No. 149 UV-C irradiance sensorUV-C irradiance at 254 nm

Zone and rope leak detection

DeviceMeasuresRadioMountRatingPower
No. 33 Zone leak detectorWater along the rope; temperature; humidityNot listedRope on the floor or in the pan; node on the wallIP67Battery, about 10 years
No. 161 Wide-temperature cable leak sensorWater leak along a sensing cableLoRaWAN Class A, North AmericaNot listed−40 to 85 °C operatingLithium battery, about 5 years (manufacturer rating)
No. 162 Printed floor leak sensorWater film across a printed sensing stripLoRaWAN Class A, North AmericaAdhesiveIP65; −20 to 60 °C operatingLithium battery, about 6 years (manufacturer rating)
No. 163 Membrane leak detectorWater leak across a membrane padLoRaWAN Class A, North AmericaWall, adhesive or cable tieIP67; −30 to 70 °C operatingLithium battery, about 10 years (manufacturer rating)
No. 164 DC-powered water rope sensorWater along a sensing ropeLoRaWAN Class A, North AmericaMagnetIP65; −20 to 55 °C operatingDC
No. 165 Battery water rope detectorWater along a sensing ropeLoRaWAN Class A, North AmericaMagnetIP65Lithium battery, about 5 years (manufacturer rating)
No. 166 Plant-room leak sensorWater leak along a sensing cableLoRaWAN, North AmericaFloor, under air handlers or around tanksNot listedBattery

Spot leak detection

DeviceMeasuresRadioMountRatingPower
No. 34 Spot leak detectorWater at the probe; temperature; humidityNot listedWall, adhesive or strapIP67; −30 to 70 °CBattery, about 10 years
No. 154 Leak & room multi-sensorWater leak, temperature, humidity, light, vibration, motion (PIR), tilt and reed-switch contactLoRaWAN Class A, North AmericaNot listed−20 to 55 °C operatingLithium battery
No. 155 Floor & drip-tray leak probeWater leak (point probe)LoRaWAN Class A, North AmericaFloor, drip tray or pipe jointNot listedBattery
No. 156 Compact leak sensorWater leak (point probe)LoRaWAN Class A, North AmericaFloor, under equipmentIP65Lithium battery
No. 157 Leak & temperature sensorWater leak (point probe) and temperatureLoRaWAN, North AmericaMagnetIP67Lithium battery, about 15 years (manufacturer rating)
No. 158 Stick-on mini leak sensorWater leak (point probe)LoRaWAN Class A, North AmericaAdhesiveIP67Lithium battery, about 5 years (manufacturer rating)
No. 159 Indoor leak sensor with remote probeWater leak (point probe)LoRaWAN Class A, North AmericaFloor, under equipmentNot listedLithium battery
No. 160 Ultra-thin drip sensorWater leak (drip) and temperatureLoRaWAN Class A, North AmericaAdhesive; strip 195 × 15 × 6 mmIP67; −20 to 60 °C operatingLithium battery, about 10 years (manufacturer rating)

Water quality

DeviceMeasuresRangeAccuracyRadioMountRatingPower
No. 35 Water-quality converterProbe-dependent: pH, ORP, conductivity/TDS, DO, turbidity, residual chlorine, temperatureNot listedNot listedNot listedWall or post by the sample pointOutdoor; −40 to 85 °CBattery
No. 167 Dissolved oxygen & temperature sensorDissolved oxygen and water temperatureDO 0–20 mg/L (0–200% saturation)±1% or ±0.1 mg/LLoRaWAN Class A, North AmericaProbe immersed in water, 7 m cableIP67Alkaline batteries
No. 168 Stainless dissolved oxygen probeDissolved oxygen0–20 mg/L (0–200% saturation)±0.1 mg/L or ±1%LoRaWAN Class A, North AmericaProbe immersed in water, 3 m cable; 316L stainless wetted parts (titanium option)IP68Lithium battery, about 5 years (manufacturer rating)
No. 169 pH, ORP & temperature sensorpH, ORP and water temperaturepH 2–12; ORP −1000 to +1000 mV; 0–50 °CpH ±0.1; ORP ±2 mV; ±0.5 °CLoRaWAN Class A, North AmericaElectrode immersed in water, 3 m cableIP68Lithium battery
No. 170 Conductivity & salinity sensorConductivity, salinity and TDSConductivity 0–200 µS/cm up to 0–200 mS/cm (4 ranges); salinity 5–60 g/kg; TDS 0–133,000 ppm±1% of full scaleLoRaWAN Class A, North AmericaProbe immersed in water, 3 m cableIP68; 0 to 50 °C operatingLithium battery, about 10 years (manufacturer rating)
No. 171 Turbidity sensorTurbidity (nephelometric, optical)5–4000 NTU (5 ranges); suspended solids 0–4500 mg/LWithin 5% of readingLoRaWAN Class A, North AmericaNot listedIP68Lithium battery
No. 172 Outdoor pH sensorpHpH 0–14±0.1 pHLoRaWAN Class A, North AmericaElectrode on a 5 m cable, in tanks or field installs−40 to 85 °C operatingLithium battery, about 10 years (manufacturer rating)

Water level and conductivity probes

All 3Radio: LoRaWAN (North America)

DeviceMeasuresRangeAccuracyMountRatingPower
No. 181 Level, temperature & conductivity probeWater depth, water temperature and electrical conductivity0 to 10 m depth; water temperature −40 to 60 °CNot listedCable-suspended probe, 10 m cableIP67; −20 to 50 °C operatingAlkaline batteries; about 10 years (manufacturer rating)
No. 182 High-precision level, temperature & conductivity probeWater level (pressure), water temperature and electrical conductivity0 to 10 mPressure ±0.1% FS; temperature ±0.1 °C; conductivity ±2.5% FSCable-suspended probe, 10 m cable; 316L stainless, titanium and PEEK wetted partsIP68; −20 to 50 °C operatingAlkaline batteries; about 4 years (manufacturer rating)
No. 183 Floating water level transmitterWater level (hydrostatic pressure) and volumeNot listed±0.25% of span, typicalFloats on the water surface; stainless steel wetted partsIP68; −20 to 85 °C operatingLithium battery; about 10 years (manufacturer rating)

Specs from the Cognituv Connect catalog (October 2026). Where the catalog gives no value, the table says “Not listed”. Confirm site suitability, calibration and current product specifications before ordering. The product data sheet governs.

Environment & water in the catalog →Ask an engineer to compare for your site →

Not sure which sensors you need?

Start from the problem you want to see. The planner suggests a gateway and monitoring points for your facility, and a Cognituv engineer confirms them.

Prefer to talk? Call 1-888-580-8738

Plan your system