Process, rooms & cold chain, side by side.

52 devices in 7 groups, each group the devices that do the same job, with the specs from the catalog. Each catalog number opens that device’s page.

Radar level

DeviceMeasuresRangeAccuracyRadioMountRatingPower
No. 21 Radar level sensorDistance to surface; level0.3–12 m; ±2 mm typical (up to ±5 mm); 1 mm resolutionNot listedNot listedTop of the vessel on a 1½-inch G or NPT tank thread, or a wall bracket; 8° beamIP68; −40 to 70 °C operatingBattery, about 5 years
No. 110 Radar distance sensor, 20 mDistance to the surface, converted to level0.5 to 20 m; 78° beam; 1 cm resolution±0.1 mLoRaWAN (North America)Above the tank, sewer or bin, facing down−20 to 85 °C operatingLithium battery; about 5 years (manufacturer rating)
No. 111 Cellular radar tank level sensorDistance to the liquid surface, converted to level; location (GPS)0.1 to 6.75 m; 8° beam; 2 mm resolutionThrough a port: ±4 mm to 2 m, ±0.75% FS from 2 to 4 m, ±2% FS beyond; non-invasive: ±2% FSCellular (LTE-M or NB-IoT)2 in adapter, or optional non-invasive adhesive-pad adapterIP68; −25 to 50 °C operatingLithium battery; about 10 years (manufacturer rating)

Ultrasonic and laser level and distance

DeviceMeasuresRangeAccuracyRadioMountRatingPower
No. 91 Laser silo & tank level sensorDistance to the surface, converted to levelUp to 40 m±50 mm under 2 m; ±1% of distance or ±25 mm from 2 mLoRaWAN (North America)Above the tank or silo, facing downIP67; −20 to 50 °C operatingAlkaline batteries; about 8 years (manufacturer rating)
No. 92 Ultrasonic water & wastewater level sensorDistance to the liquid surface, converted to levelNot listed±1% or better (factory calibrated)LoRaWAN (North America)Above the tank or sump, facing down, at least 0.3 m above the highest liquid levelIP67; −20 to 50 °C operatingAlkaline batteries; about 7 years (manufacturer rating)
No. 93 Waste bin fill sensorFill height, temperature and tilt0.15 to 4 mHeight ±3 cm; temperature ±2 °C; tilt ±2°LoRaWAN (North America)Top cover or side mount with bracketIP68; −30 to 85 °C operatingLithium battery; about 3 years (manufacturer rating)
No. 94 Ultrasonic distance sensor, 4.5 or 7.5 mDistance to the surface, converted to level30 mm to 4.5 m or 0.28 to 7.5 m±(1 cm + 0.3% of distance)LoRaWAN (North America)Above a flat liquid or solid surface, probe facing it; 60° beam (4.5 m) or 40° beam (7.5 m)IP66; −40 to 85 °C operatingLithium battery; about 5 years (manufacturer rating)
No. 95 Short-range laser distance sensorDistance to the nearest object or surface3 cm to 2 m±2 cm from 3 cm to 1 m; ±5% from 1 to 2 mLoRaWAN (North America)Facing the target, 3 cm to 2 m away; 18° beamIndoor; −40 to 80 °C operatingBattery or DC
No. 96 Four-channel ultrasonic distance sensorDistance at up to four points, converted to levelNot listed±(1 cm + 0.3% of distance)LoRaWAN (North America)Node nearby; each probe above its surface, facing downIP67Lithium battery
No. 97 Narrow-beam laser level sensor, 12 or 40 mDistance to the surface, converted to level0.1 to 12 m or 0.1 to 40 m12 m version: ±5 cm from 0.1 to 5 m; ±1% from 5 to 12 mLoRaWAN (North America)Above the surface, probe facing down; 3.6° beam (12 m) or 3° beam (40 m)IP65; −40 to 85 °C operatingLithium battery; about 5 years (manufacturer rating)
No. 98 Cellular ultrasonic distance sensorDistance to the surface, converted to level0.28 to 7.5 m±(1 cm + 0.3% of distance)Cellular (LTE or NB-IoT), SIM includedAbove a flat liquid or solid surface, probe facing itIP66; −40 to 85 °C operatingLithium battery; about 5 years (manufacturer rating)
No. 99 Corrosion-resistant ultrasonic level sensorDistance to the surface, converted to levelUp to 10 mNot listedLoRaWAN (North America)Above the tank, facing the liquidIP68; parylene-coated transducer, POM housing; −20 to 85 °C operatingLithium battery; about 10 years (manufacturer rating)
No. 100 Ultrasonic pit & tank level sensorDistance to the surface, converted to levelUp to 5 mNot listedLoRaWAN (North America)Above the tank or pit, facing the liquidIP65; −20 to 85 °C operatingLithium battery; about 10 years (manufacturer rating)
No. 101 Compact ultrasonic distance sensorDistance to the contents, converted to level3 cm to 4.5 m±(1 cm + 0.3% of distance); 1 mm resolutionLoRaWAN (North America)Surface mount with screws, facing the target; 60° beamIP67; −15 to 60 °C operatingLithium battery; about 10 years (manufacturer rating)
No. 102 Multi-purpose ultrasonic distance sensorDistance, fill level and temperature3 cm to 4.5 m; 60° beamNot listedLoRaWAN (North America)Surface mount with screwsIP67; −30 to 70 °C operatingLithium battery; about 10 years (manufacturer rating)
No. 103 Weatherproof laser distance sensorDistance, fill level and temperature2 cm to 3.5 m; 27° beam; 1 mm resolution±2 cm (−20 to 70 °C)LoRaWAN (North America)Surface mount with screws, facing the targetIP67; −30 to 70 °C operatingLithium battery; about 10 years (manufacturer rating)
No. 104 Container fill-level sensorDistance to the contents, converted to fill level1 to 55 cm±1 cmLoRaWAN (North America)Adhesive tape inside the containerIP30, indoor; −10 to 60 °C operatingLithium battery; about 2 years (manufacturer rating)
No. 105 Ultrasonic level sensor, 5 or 10 mDistance to the surface, level and temperatureUp to 5 m or 10 m, by version±(1 cm + 0.3% of distance)LoRaWAN (North America)Surface mount with screws, above the targetIP67; −30 to 70 °C operatingLithium battery; about 10 years (manufacturer rating)
No. 106 Threaded tank level monitorLiquid level and temperatureUp to 5.8 mNot listedLoRaWAN (North America)Threads into a 1 in NPT tank portIP67; −40 to 60 °C operatingBattery; about 5 years (manufacturer rating)
No. 107 Intrinsically safe tank level monitorLiquid level and temperatureUp to 3 mNot listedLoRaWAN (North America)Threads into a 1 in NPT tank portIP67; −40 to 60 °C operatingBattery; about 5 years (manufacturer rating)
No. 108 Fuel & water tank level sensorDistance to the liquid surface, converted to level0.12 to 4 m; 30° beam±2 cm typicalLoRaWAN (North America)Threads into a 2 in BSP port on the tank topIP67; −20 to 50 °C operatingLithium battery; about 14 years (manufacturer rating)

Submersible, pressure and capacitive level

All 9Radio: LoRaWAN (North America)

DeviceMeasuresAccuracyMountRatingPower
No. 83 Submersible level & temperature probe, 10 mLiquid level (hydrostatic pressure) and liquid temperature±0.5% FS total error band; 0.3 mm resolution; temperature ±2 °C typicalCable-suspended 316L stainless probe, 10 m cableIP68; −20 to 50 °C operatingAlkaline batteries; about 11 years (manufacturer rating)
No. 84 High-precision submersible level & temperature probeLiquid level (hydrostatic pressure) and liquid temperaturePressure ±0.1% FS total error band; temperature ±0.3 °CCable-suspended 316L stainless probe, 10 m cableIP68; −20 to 50 °C operatingAlkaline batteries; about 10 years (manufacturer rating)
No. 85 Submersible tank level transmitter with temperatureLiquid level (hydrostatic pressure) and temperature±0.25% of span, typicalCable-suspended 304/316 stainless probe, no process connectionIP68; −20 to 85 °C operatingLithium battery; about 10 years (manufacturer rating)
No. 86 Corrosive liquid level transmitterLiquid level (hydrostatic pressure)±0.25% of span, typicalCable-suspended probe, no process connectionIP68; −20 to 85 °C operatingLithium battery; about 10 years (manufacturer rating)
No. 87 Low-power submersible level transmitterLiquid level (hydrostatic pressure)±0.25% of span, typicalCable-suspended probe, no process connectionNot listedLithium battery; about 10 years (manufacturer rating)
No. 88 Submersible level transmitter, 1 m cableLiquid level (hydrostatic pressure)±0.25% of span, typicalCable-suspended probe, 1 m cableIP68; −20 to 85 °C operatingLithium battery; about 10 years (manufacturer rating)
No. 89 Capacitive level sensorLiquid level at the electrode padNot listedAdhesive electrode pad on the tank wallIP67; indoor useLithium battery
No. 90 Submersible water level sensorWater level (hydrostatic pressure)±0.5% FS; 0.01 m resolutionCable-suspended 304 stainless probeIP68; −30 to 70 °C operatingLithium battery; about 10 years (manufacturer rating)
No. 109 Thread-in level & temperature sensorHydrostatic pressure, converted to liquid level; liquid temperature±0.7% FS total error band; temperature ±2 °C typicalThreads into a 1/4 in NPT tank port; 2 m cable to the radio unitIP67; −20 to 50 °C operatingAlkaline batteries; about 10 years (manufacturer rating)

Pressure, tilt and position

DeviceMeasuresRangeMountRatingPower
No. 22 Pipe pressure sensor, 0–16 barGauge pressure, liquid or gas0–16 barProbe threads into the line; transceiver on a 1.5 m cable mounts on a wall, pole or DIN railIP65; −10 to 70 °C operatingBattery, about 10 years (manufacturer rating)
No. 23 Differential pressure, rooms & filtersDifferential pressure; temperature; humidityNot listedWall, with tubing to each sideIndoorBattery
No. 24 Tilt & position sensorTilt angle on three axes; movement events±90°; ±1°Bolt or adhesive on the structureIP67; −30 to 60 °C operatingBattery, about 3 years

Temperature probes

All 6Radio: LoRaWAN (North America)

DeviceMeasuresRangeAccuracyInputsMountRatingPower
No. 25 Food-safety temperature, 2-channelTemperature on two probes−40 to 260 °C probe; ±0.5 °C (0–80 °C), Class A PT100Not listedNot listedProbes in the tank or room; transmitter outside the washdown zone (−40 to 65 °C)Food-safety type, IP65 transmitterLithium battery
No. 26 Ultra-low PT100 probe, −196 °CTemperature on two probes−196 to 150 °C; ±0.5 °C (0–80 °C)Not listedNot listedWall transmitter; 2 m probe leadsTransmitter −40 to 65 °CLithium battery
No. 78 Long-reach temperature probeTemperature−55 to 125 °CBetter than ±0.5 °C from −10 to 85 °COne temperature probe on a 5 m cableNot listedIP67; node operates −20 to 50 °CAlkaline batteries, about 11.6 years (manufacturer rating)
No. 80 Insertion temperature sensorTemperature−30 to 70 °C±0.5 °C typical316 stainless steel insertion probeNot listedIP67Lithium battery, about 10 years (manufacturer rating)
No. 81 Temperature probe node with displayTemperature from PT100 probes; door open or closed on a channelNot listedNot listedOne or two PT100 probe channels; a channel can take a door contactWall or magnetIP65; operates −30 to 70 °CBattery or DC
No. 82 Multi-point HVAC temperature nodeTemperature at three points−55 to 125 °C±0.5 °C (−10 to 85 °C); 0.1 °C resolutionThree temperature probes on 1 m leadsNot listedNot listedLithium battery, about 3 years (manufacturer rating)

Temperature and humidity

All 6Radio: LoRaWAN (North America)

DeviceMeasuresRangeAccuracyMountRatingPower
No. 27 Magnet-mount temperature & humidity, IP67Temperature and relative humidity−30 to 60 °C; ±0.2 °C (0–60 °C), ±0.3 °C (−30 to 0 °C), ±2% RHNot listedMagnetIP67; PC+ABS housingBattery, about 10 years
No. 74 Room temperature & humidity sensorTemperature and relative humidityNot listed±2 %RH typicalWallIndoor; operates 5 to 50 °CBattery
No. 75 Compact room temperature & humidity sensorTemperature and relative humidity−20 to 50 °C±0.3 °C typical; ±3 %RH typical (20 to 80 %RH)WallIP52, indoorAlkaline batteries
No. 76 Temperature & humidity sensor with probe portTemperature and relative humidity; illuminance on the light-probe version−40 to 80 °C±0.3 °C and ±3 %RH typicalWallNot listedLithium battery, about 10 years (manufacturer rating)
No. 77 Damp-room temperature & humidity sensor, IP67Temperature and relative humidity−30 to 70 °C±0.3 °C (0 to 70 °C), ±0.6 °C (−30 to 0 °C); ±3 %RH (10 to 90 %RH), typicalWallIP67Lithium battery, about 10 years (manufacturer rating)
No. 79 Precision temperature & humidity probeTemperature and relative humidity−40 to 125 °C±0.1 °C (20 to 60 °C), ±0.2 °C (−40 to 90 °C); ±1.5 %RH (0 to 80 %), ±2 %RH (80 to 100 %)Not listedIP67; node operates −20 to 50 °CAlkaline batteries, about 12.2 years (manufacturer rating)

Doors and open/close contacts

All 7Radio: LoRaWAN (North America)

DeviceReadsRangeMountRatingPower
No. 28 Door contact, IP67Not listedNot listedScrew, adhesive or strapIP67; −30 to 70 °CBattery, about 10 years
No. 112 Outdoor dry-contact sensorDry-contact state, open count, last-open durationNot listedNot listedIP67; −40 to 85 °C operating8,500 mAh lithium battery, about 5 years (manufacturer rating)
No. 113 Outdoor door & gate sensorOpen and close eventsUp to 45 mm magnet gapWall; reed sensor on a 0.4 m cable−40 to 85 °C operatingLithium battery, about 5 years (manufacturer rating)
No. 114 Indoor door & window sensorOpen and close statusUp to 10 mm magnet gapScrew or adhesiveNot listedBattery (alkaline)
No. 115 Slim door & window contactOpen and close stateUp to 20 mm magnet gapAdhesiveIP30 (indoor); −20 to 55 °C operatingLithium battery
No. 116 Door & window contact with tamper alertOpen, close and tamperUp to 20 mm magnet gapScrew or adhesiveIP20 (indoor); −20 to 60 °C operatingLithium battery, about 4 to 7 years (manufacturer rating)
No. 117 Two-channel open/close sensorOpen and close stateUp to 20 mm magnet gapMagnet; contact on a 1 m cableIP65; −20 to 55 °C operatingLithium battery

Specs from the Cognituv Connect catalog (October 2026). Where the catalog gives no value, the table says “Not listed”. Confirm site suitability, calibration and current product specifications before ordering. The product data sheet governs.

Process, rooms & cold chain in the catalog →Ask an engineer to compare for your site →

Not sure which sensors you need?

Start from the problem you want to see. The planner suggests a gateway and monitoring points for your facility, and a Cognituv engineer confirms them.

Prefer to talk? Call 1-888-580-8738