Occupancy & building controls, side by side.

41 devices in 8 groups, each group the devices that do the same job, with the specs from the catalog. Each catalog number opens that device’s page.

Room occupancy

DeviceMeasuresRangeRadioMountRatingPower
No. 184 Room presence & comfort sensorPresence (occupied or vacant), motion, temperature, humidity and lightDetection up to 5 m, 60° beam (manufacturer rating)LoRaWAN, North American bandCeiling or wall, screw fixedIndoor, 0 to 50 °CLithium battery, about 5 years (manufacturer rating)
No. 185 AI workplace occupancy sensorPeople count in its field of view, by desk and roomCoverage about 128 m² with a 190° beam (standard) or 77 m² with a 129.4° beam (high-ceiling version) (manufacturer rating)Not listedCeilingIP30, indoor, −5 to 55 °CDC (LoRaWAN versions); PoE or DC (PoE versions)
No. 186 Restroom occupancy sensorPresence (occupied or vacant) by time-of-flight and PIRDetection up to 3.5 m, 27° beam (manufacturer rating)LoRaWAN, North American bandCeiling or wallIP30, indoor, −20 to 60 °CLithium battery, about 4.2 years (manufacturer rating)
No. 187 Motion & light sensorOccupancy by PIR motion and light levelDetection up to 8 m, 120° beam (manufacturer rating)LoRaWAN, North American bandScrews or adhesiveIP30, indoor, −20 to 60 °CLithium battery, about 4 years (manufacturer rating)
No. 188 Occupancy, temperature & light sensorPresence (occupied or vacant), temperature and lightDetection up to 12 m, 110° beam (manufacturer rating)LoRaWAN, North American bandWall, adhesiveIP30, indoor, −20 to 55 °CLithium battery
No. 189 Compact room occupancy sensorPresence (occupied or vacant), temperature, humidity and lightDetection up to 5 m, 70° beam (manufacturer rating)LoRaWAN, North American bandWall, ceiling or desktopIP30, indoor, 0 to 60 °CLithium battery

Desk occupancy

All 3Radio: LoRaWAN, North American band

DeviceMeasuresRangeMountRatingPower
No. 190 Desk occupancy sensorDesk presence (occupied or vacant) by PIR motionDetection up to 1 m, 107° beam (manufacturer rating)Desk or wall, screws or adhesiveIP30, indoor, −20 to 60 °CLithium battery, about 5 years (manufacturer rating)
No. 191 Thermal desk occupancy sensorDesk presence (occupied or vacant) by PIR and thermal arrayDetection up to 1 m, 107° beam (manufacturer rating)Desk (on or under) or wall, screws or adhesiveIP30, indoor, −20 to 60 °CLithium battery, about 5 years (manufacturer rating)
No. 192 PIR motion & desk sensorPresence (occupied or vacant) by PIR motionDetection up to 7 m, 123° beam (manufacturer rating)Desktop or wallIP50, indoor, 0 to 50 °CLithium battery

People counters

DeviceMeasuresAccuracyRadioMountRatingPower
No. 194 Doorway people counterPeople passing through an opening (infrared breakbeam)Up to 99% for single-file traffic (manufacturer rating)LoRaWAN, North American bandWall, 1.25 to 1.4 m highIP20, indoor, 0 to 40 °CBattery
No. 195 Paired-beam people counterPeople in and out through an openingUp to 90% (manufacturer rating)LoRaWAN, North American bandWall, 0.7 to 1.2 m highIP30, indoor, −20 to 50 °CBattery
No. 196 Stereo vision people counterPeople in and out, zone counts, dwell time, U-turns and heat map, with staff exclusionUp to 99.8% (manufacturer rating)LoRaWAN, North American bandCeiling, 2.2 to 6 m highIP40, indoor, −20 to 50 °CPoE or DC
No. 197 Time-of-flight people counterPeople in and out, zone counts, dwell time, queues, U-turns and heat map, with staff exclusionUp to 99.8% (manufacturer rating)Not listedCeiling, 2.5 to 3.5 m highIP40, indoor, −20 to 50 °CDC (LoRaWAN version) or PoE (Ethernet version)
No. 198 Large-entry people counterPeople in and out, zone counts, dwell time, queues, U-turns and heat map, with staff exclusionUp to 99.8% (manufacturer rating)Not listedCeiling, 2.5 to 3.5 m standard or 3.5 to 6.5 m high-ceilingIP40, indoor, −20 to 50 °CDC (LoRaWAN versions); PoE or DC (PoE versions)
No. 199 Dual-PIR people counterPeople passing through corridors and doorwaysUp to 95% single file, 80% in groups (manufacturer rating)LoRaWAN, North American bandCeiling or wall, 1.2 to 3 m highIP30, indoor, −20 to 60 °CBattery
No. 200 Mini thermal people counterPeople passing through smaller openings80 to 90% (manufacturer rating)LoRaWAN, North American bandCeiling, 2 to 3 m highIP30, indoor, −20 to 60 °CDC

Buttons and request terminals

DeviceReadsRadioRatingPower
No. 201 Weatherproof counting buttonButton presses (count)LoRaWAN (North America)IP67, outdoorBattery
No. 202 Compact push buttonButton pressesLoRaWAN (North America)IP30, indoor, −20 to 60 °CLithium battery, about 9 years (manufacturer rating)
No. 203 Wide-temperature push buttonButton pressesLoRaWAN (North America)IP30, indoor, −40 to 70 °CLithium battery
No. 204 Cellular service request terminalService requests and NFC staff clock-ins4G/LTE-M cellular, no gateway neededIndoorBattery
No. 220 Panic buttonButton press (duress alert)LoRaWAN (North America)Not listedNot listed

Relays, I/O and lighting controllers

DeviceReadsInputsOutputsRadioMountRatingPower
No. 205 Relay and I/O controllerDigital and analog (voltage, current) inputsNot listedDigital and relay outputs, 2 channels, 5 A maxLoRaWAN (North America), external antennaNot listed−40 to 85 °C operatingDC
No. 206 Single-channel relay, 15 ANot listedNot listedOne relay, up to 15 ALoRaWAN (North America)Not listed−40 to 70 °C; flame-retardant, UV-resistant polycarbonate housing80–275 VAC mains
No. 207 Multi-interface I/O controllerDigital and analog (voltage, current) inputs, PT100/RTD temperatureRS485 and RS232 serialRelay, 3 A maxLoRaWAN (North America), external antennaDIN rail, wall or desktopIP30, indoor, −20 to 60 °CDC
No. 208 Solar-powered outdoor I/O controllerDigital, pulse and analog (voltage, current) inputsRS485, RS232 and SDI-12 serialDigital outputsLoRaWAN Class C (North America)Wall or poleIP68, outdoor, −20 to 60 °CSolar with lithium-ion battery, or DC
No. 209 Battery-powered outdoor I/O controllerDigital, pulse and analog (voltage, current) inputsRS485, RS232 and SDI-12 serialDigital outputsLoRaWAN Class A (North America)Wall or poleIP68, outdoor, −30 to 70 °CLithium thionyl chloride battery, or DC
No. 210 Eight-circuit light controllerNot listedNot listed8 relay circuits; 16 A max (line-and-neutral version), 10 A max (switch version)LoRaWAN (North America)Wall or DIN railIndoor, −20 to 60 °C100–240 VAC mains

Displays, panels, switches and thermostat

All 6Radio: LoRaWAN (North America)

DeviceDisplayMountRatingPower
No. 211 E-ink room displayE-inkWall or adhesiveIP30, indoor, 0 to 40 °CBattery, about 5 years (manufacturer rating)
No. 212 LCD room displayLCDWall, adhesive or desktopIP30, indoor, −10 to 60 °CPoE or DC
No. 215 Six-button scene panelNot listedWall, adhesive or desktopIP30, indoor, −10 to 50 °CLithium battery, about 3 years (manufacturer rating)
No. 216 Six-button scene panel with displayE-inkWall, adhesive or desktopIP30, indoor, −10 to 50 °CLithium battery, about 3 years (manufacturer rating)
No. 217 Smart wall switchNot listedWall boxIP20, indoor, −20 to 60 °C100–250 VAC mains
No. 218 Smart thermostatLCD with 5 buttonsWall, in place of a 24 VAC thermostatIP30, indoor, −20 to 60 °C24 VAC (±15%)

Smoke, CO, vape and siren

DeviceMeasuresRadio
No. 221 Vape detectorVaping eventsLoRaWAN (North America)
No. 222 Vape & sound detectorVaping and sound events (LoRaWAN or cellular version)LoRaWAN (North America) or cellular
No. 223 Wireless sirenNot listedLoRaWAN (North America)
No. 224 Wireless smoke detectorSmokeLoRaWAN (North America)
No. 225 Wireless carbon monoxide detectorCarbon monoxide (CO)LoRaWAN (North America)

Parking, window and pest sensors

DeviceReadsRadioMountRatingPower
No. 193 Parking space sensorNot listedLoRaWAN, North American bandIn-ground in saw-cut pavement, or surface adhesiveIP67, outdoor, −30 to 70 °CLithium battery, about 7 years (manufacturer rating)
No. 219 Window contact with glass-break detectorWindow open and close (magnetic reed), glass breakLoRaWAN (North America)AdhesiveIP30 (indoor); −20 to 55 °C operatingLithium battery
No. 226 Connected rodent trapCatch eventLoRaWAN, North AmericaNot listedNot listedNot listed

Specs from the Cognituv Connect catalog (October 2026). Where the catalog gives no value, the table says “Not listed”. Confirm site suitability, calibration and current product specifications before ordering. The product data sheet governs.

Occupancy & building controls in the catalog →Ask an engineer to compare for your site →

Not sure which sensors you need?

Start from the problem you want to see. The planner suggests a gateway and monitoring points for your facility, and a Cognituv engineer confirms them.

Prefer to talk? Call 1-888-580-8738

Plan your system