Modbus bridge
CGUV-CTRL-MILE-004
Reads Modbus RS485 devices and brings their data onto the Cognituv Connect dashboard, such as compressor kW, oven setpoints and refrigeration pressures, from controllers already installed.
- RS485 · Modbus
- Class C
- DC powered
- 70 × 45 mm
Specifications
At a glance.
| Reads | Modbus RTU over RS485 |
|---|---|
| Devices | Compressor, oven, dryer and refrigeration controllers; existing meters and drives |
| Mount | Wall or desktop beside the controller |
| Rating | IP30, indoor |
| Power | DC |
| SKU | CGUV-CTRL-MILE-004 |
Confirm site suitability, calibration and current product specifications before ordering. The product data sheet governs.
Request the data sheet →Where it fits
Typical places for the Modbus bridge.
Food & beverage
Refrigeration, compressor, dryer and oven controllers
General manufacturing
Compressor and generator controllers; CNC and press counts; DCS points
Automotive
Compressor controllers; press and molder cycle counts
Warehousing & distribution
Sorter PLC counts and faults; refrigeration controller
Recommended for
- Aerospace
- Automotive Manufacturing
- Construction
- Data Centers
- Defense Manufacturing
- Education
- Food & Beverage Manufacturing
- General Manufacturing
- Government
- Heavy Equipment & Transportation
- Healthcare
- Life Sciences
- Marine
- Oil & Gas
- Power Generation
- Recreational Vehicle Manufacturing
- Commercial Real Estate & Offices
- Hospitality
More in energy & utilities
All energy & utilities →12-channel electrical sub-meter
CGUV-ENGY-EWAT-001DIN-rail sub-meter with snap-on clamps and voltage inputs, reporting kW, kWh, power factor and reactive power for each circuit, so energy can be allocated by line, shop or room.12 channelskWh · kW · PFUp to 600 ASpecs and usesEnergy & utilities250 A smart current sensor
CGUV-ENGY-MILE-002Clamps around one conductor and reports amps and amp-hours; the detachable radio mounts outside a metal panel. Typical uses are individual presses, molders, sorter drives, dust-collector fans and defrost heaters.250 A split-core±1% (> 5 A)Self-poweredSpecs and usesEnergy & utilities3-phase current meter, 1000 A
CGUV-ENGY-MILE-004Three 1000 A split-core clamps for main feeders and large motor control centers, showing the plant's load profile by shift. Split-core clamps install without disconnecting conductors.3 × 1000 A±1%Self-powered or DCSpecs and usesPut the Modbus bridge to work.
The planner builds a gateway and sensor schedule around the problem you want to see. A Cognituv engineer confirms placement and coverage, then sends a quote.