Sites and outdoor assets: what to measure, and where it goes.
Fence-line air, noise and weather, structure tilt, stormwater discharge and gas skids.
Construction site or yard perimeter
Dust, gases, sound and weather
Sound familiar? “When something happens on site, it’s our word against theirs.”
| Sensors | |
|---|---|
| Where it goes | Air-quality and sound stations on poles at the fence line on the sensitive (downwind or neighbor) sides; the weather station on a mast clear of buildings. |
| How it mounts | Pole or mast, reporting through an outdoor cellular gateway (No. 39). |
| How many | Two or more fence-line points per site |
| What it reads | Particulates, gases, weather and sound (dB) |
| What it catches | Dust and noise events |
| What you get | A time-stamped record before a complaint becomes a stop-work order |
| Pairs with |
Hoist, scaffold or structure
Tilt
| Sensor | |
|---|---|
| Where it goes | Bolted to the structure at a point that moves with it. |
| How it mounts | Bolt or adhesive. |
| How many | One per structure |
| What it reads | Tilt angle; movement events |
| What it catches | Movement, settling |
Stormwater outfall or discharge
pH and level
| Sensors | |
|---|---|
| Where it goes | pH electrode in the discharge channel or sump; ultrasonic level sensor over the channel. |
| How it mounts | Electrode on a 5 m cable; bracket for the level sensor. |
| How many | One pH electrode and one level sensor per outfall |
| What it reads | pH; level |
| What it catches | Out-of-range discharge |
Gas skid, compressor station or wellhead
Vibration, gas pressure drop, tilt and fence-line air
| Sensors | |
|---|---|
| Where it goes | Explosion-proof vibration monitors on compressor and blower bearings inside the zone; gas pressure drop across the filters and the polisher; tilt on the skid; an air station at the fence line. |
| How it mounts | Work under the site’s hazardous-area permits; only explosion-proof devices go inside the zone. |
| How many | Set per skid at the assessment |
| What it reads | Vibration; differential pressure; tilt; fence-line air |
| What it catches | Bearing faults, loaded filters, skid movement, emissions at the fence line |
| Pairs with |
Placement and quantities are starting points from Cognituv’s install guidance. A Cognituv engineer confirms them for your site, and the product data sheet governs. Electrical and hazardous-area work follows the site’s own rules and permits.
Have an equipment list?
Upload it in the planner. It suggests what to measure on each asset and a gateway to carry it, and a Cognituv engineer confirms the plan.
Prefer to talk? Call 1-888-580-8738