Rooms and occupied spaces: what to measure, and where it goes.

Indoor air, ventilation, odor, vaping, room pressure, warehouse air, grow rooms and server rooms.

Office, conference room or open plan

Indoor air (CO₂, TVOC, particulates, temperature, humidity)

Sound familiar? “Tenants keep asking whether the air is OK.”

Sensors
Where it goesOn a wall in the breathing zone, about 0.9 to 1.8 m (3 to 6 ft) high, away from doors, windows, supply diffusers, printers and people’s direct breath.
How it mountsWall mount; battery or DC power.
How manyOne per room or open-plan zone; an engineer sizes large floors at the assessment
What it readsCO₂, TVOC, PM2.5, PM10, temperature, humidity, pressure, light and motion
What it catchesUnder-ventilation, pollutant sources, comfort complaints
What you getRoom-level evidence for ventilation and comfort questions
Pairs with
Add No. 29 to a plan →

Classroom

CO₂ and temperature

Sensor
Where it goesOn a wall in the breathing zone, away from the door and the unit ventilator discharge.
How it mountsWall mount; display optional.
How manyOne per classroom
What it readsCO₂, temperature and humidity
What it catchesUnder-ventilated rooms
What you getRoom-by-room ventilation evidence for the district
Pairs with
Add No. 141 to a plan →

Restroom

Odor (ammonia, hydrogen sulfide) and occupancy

Sensors
Where it goesOdor sensor on the wall in the room, away from the exhaust grille; occupancy sensor on the ceiling or wall within its 3.5 m range.
How it mountsBattery powered; no camera.
How manyOne odor sensor per restroom; one occupancy sensor per room or stall
What it readsAmmonia, hydrogen sulfide, temperature and humidity; occupied or vacant
What it catchesOdor events; cleaning needed by use
What you getCleaning on use and odor instead of the clock
Add No. 127 to a plan →

School restroom or locker room

Vape events

Sensor
Where it goesOn the ceiling in the room, away from the exhaust fan.
How it mountsCeiling mount; no camera.
How manySet per room at the assessment
What it readsVaping events
What it catchesVaping
Add No. 221 to a plan →

Isolation or pressurized room

Room-to-corridor pressure

Sensor
Where it goesSensor at the room door, with the reference tube through the wall to the corridor or anteroom.
How it mountsWall mount; tubing through a sleeve.
How manyOne per pressurized room
What it readsDifferential pressure (Pa)
What it catchesLoss of the pressure relationship from doors or exhaust faults
What you getA continuous pressure record for the infection-prevention team
Pairs with
Add No. 23 to a plan →

Warehouse, dock or forklift area

Carbon monoxide and particulates

Sensors
Where it goesCarbon monoxide detector on a column near the dock and the charging or propane areas; particulate monitor at a fixed point.
How it mountsScrew mount; battery powered.
How manyOne carbon monoxide detector per zone; particulate points set at the assessment
What it readsCarbon monoxide; particulates
What it catchesForklift exhaust building up; dust
Add No. 225 to a plan →

Grow room (indoor agriculture)

CO₂ (high range), temperature and humidity

Sensor
Where it goesAt canopy height, away from CO₂ injection points and fans.
How it mountsWall, pole or DIN rail; IP65.
How manyOne per room or zone
What it readsCO₂, temperature, humidity and pressure
What it catchesCO₂ enrichment off; humidity out of range
Add No. 126 to a plan →

Server room or IT closet

Leak and temperature

Sensors
Where it goesRope around the base of the CRAC or split unit, along the raised-floor perimeter and under condensate lines; temperature and humidity at rack inlet height.
How it mountsClips for the rope; adhesive for the room sensor.
How manyOne rope and one or two temperature sensors per room
What it readsWater; temperature; humidity
What it catchesCondensate leaks, cooling failure
What you getUptime evidence on a cellular data path
Add No. 33 to a plan →

Placement and quantities are starting points from Cognituv’s install guidance. A Cognituv engineer confirms them for your site, and the product data sheet governs. Electrical and hazardous-area work follows the site’s own rules and permits.