Cognituv Connect · Sensor catalog

Find your starting point.

35 wireless sensors and gateways for equipment, utilities, cold chain and indoor air, all supplied by Cognituv. Filter by family or industry, open a product for its specs, then plan a system around the problem you want to see.

35 products

Catalog Rev 5 · October 2026
Connectivity & gateways

Industrial gateway: Ethernet, Wi-Fi or cellular

CGUV-GW-MILE-CELL-001Industrial LoRaWAN gateway that can send data over Ethernet, Wi-Fi or its own cellular connection, and switches to a second connection if the first one drops. Rated for hot, cold and dusty areas, so it can sit on a mezzanine, in a mechanical room or under an eave.Ethernet · Wi-Fi · LTEAutomatic failoverIP65Specs and uses
Connectivity & gateways

Ethernet gateway

CGUV-GW-GEMT-ETH-001Indoor LoRaWAN gateway that uses the plant's wired network. The simplest way to cover an office, lab, warehouse or production floor where a network port is already in place and IT approves IoT devices on the LAN.Ethernet8-channelIndoorSpecs and uses
Connectivity & gateways

Indoor cellular gateway

CGUV-GW-TEKL-CELL-002Compact LoRaWAN gateway with its own multi-carrier cellular connection, two SIM slots and battery backup. Data never touches the plant network, so it is the usual choice when IT keeps new devices off the LAN or the site needs to start quickly.8-channel2 SIM slotsPoE or DCSpecs and uses
Connectivity & gateways

Outdoor IP67 gateway

CGUV-GW-MULT-CELL-001Pole- or wall-mounted LoRaWAN base station with cellular backhaul and GPS for yards, tank farms, docks and multi-building sites. Covers outdoor areas and the space between buildings that an indoor gateway cannot reach.IP67−40 to 70 °CPoESpecs and uses
Rotating equipment & heat

Vibration & temperature monitor

CGUV-STRUC-AVAN-001Three-axis vibration and surface temperature with on-board condition analytics, mounted by magnet or stud on the bearing housing. Trending vibration and temperature shows bearing wear before it causes a failure.3-axis · ±16 gVelocity RMS · kurtosis · crestIP66Specs and uses
Rotating equipment & heat

Explosion-proof vibration monitor

CGUV-STRUC-AVAN-002The same three-axis vibration and temperature sensor, certified for hazardous locations. Use it in classified areas such as flour, feed, carbon-black and solvent handling, and use No. 5 elsewhere.ATEX / IECExZone 0 / 1 / 2±16 gSpecs and uses
Rotating equipment & heat

Infrared surface-temperature sensor

CGUV-TEMP-DECL-001Non-contact infrared measurement of surfaces up to 1030 °C, including bearing housings, oven and kiln shells, dryer drums, compressor heads, and the lugs and breakers in a motor control center.−40 to 1030 °CNon-contactIP67Specs and uses
Rotating equipment & heat

3-phase current meter, 500 A

CGUV-ENGY-MILE-003Three split-core clamps on one self-powered node report current, amp-hours and phase balance on a motor feeder, showing single-phasing, overload heating and motors left running when the line is idle.3 × 500 A clamps±1%Self-poweredSpecs and uses
Rotating equipment & heat

High-temperature probe, 500 °C

CGUV-TEMP-MILE-004PT100 RTD probe on a sealed wireless transmitter for ovens, dryers, steam lines, heat-treat furnaces and exhaust ducts.−50 to 500 °C±0.5 °C to 170 °CIP67Specs and uses
Rotating equipment & heat

High-temperature probe, 800 °C

CGUV-TEMP-MILE-005The same industrial transmitter with a probe rated to 800 °C, for furnace zones, forging, die- cast holding furnaces and kiln exhaust.−50 to 800 °CPT100IP67Specs and uses
Rotating equipment & heat

Waterproof PT100 probe, 200 °C

CGUV-TEMP-DRAG-014Two-channel transmitter with waterproof braided-metal PT100 probes for compressor discharge, aftercooler outlet, CIP supply and steam condensate.−50 to 200 °C2 channelsClass A PT100Specs and uses
Rotating equipment & heat

Three-probe temperature node

CGUV-TEMP-DRAG-004One outdoor-rated node with three probes, used for the floor, middle and ceiling of a cold room, three oven zones or three tanks.3 probes−55 to 125 °CIP66Specs and uses
Energy & utilities

12-channel electrical sub-meter

CGUV-ENGY-EWAT-001DIN-rail sub-meter with snap-on clamps and voltage inputs, reporting kW, kWh, power factor and reactive power for each circuit, so energy can be allocated by line, shop or room.12 channelskWh · kW · PFUp to 600 ASpecs and uses
Energy & utilities

250 A smart current sensor

CGUV-ENGY-MILE-002Clamps around one conductor and reports amps and amp-hours; the detachable radio mounts outside a metal panel. Typical uses are individual presses, molders, sorter drives, dust-collector fans and defrost heaters.250 A split-core±1% (> 5 A)Self-poweredSpecs and uses
Energy & utilities

3-phase current meter, 1000 A

CGUV-ENGY-MILE-004Three 1000 A split-core clamps for main feeders and large motor control centers, showing the plant's load profile by shift. Split-core clamps install without disconnecting conductors.3 × 1000 A±1%Self-powered or DCSpecs and uses
Energy & utilities

Pulse counter

CGUV-ENGY-MILE-005Turns the plant's existing water, gas, steam and electric meters into wireless meters, so water use can be tracked by line and gas use by oven batch.Pulse / S0 inputIP675-yr batterySpecs and uses
Energy & utilities

Air & liquid line pressure

CGUV-PRES-DRAG-004Pressure transmitter on a ¼-inch NPT fitting. On the compressed-air header it records the off-shift pressure decay used to estimate leaks; on a dust collector it confirms that pulse-jet cleaning pressure stays in range.¼" NPT±0.2% FSAir & liquidSpecs and uses
Energy & utilities

Differential pressure, air & gas

CGUV-PRES-ELLN-001Industrial differential-pressure sensor across compressed-air filters, dryers and separators, the pressure-drop measurement DOE uses as a baseline. Filters can be changed on measured pressure drop instead of a schedule.Differential±0.2% span⅛" NPTSpecs and uses
Energy & utilities

Water flow meter, DN25

CGUV-FLOW-DRAG-DN25-001In-line turbine meter for 1-inch lines, reporting flow rate and total volume, so washdown, CIP, rinse, make-up and shower water can be measured by shift.DN25 (1 in.)2–100 L/min±5%Specs and uses
Energy & utilities

Modbus bridge

CGUV-CTRL-MILE-004Reads Modbus RS485 devices and brings their data onto the Cognituv Connect dashboard, such as compressor kW, oven setpoints and refrigeration pressures, from controllers already installed.RS485 · ModbusClass CDC poweredSpecs and uses
Process, rooms & cold chain

Radar level sensor

CGUV-LVL-MILE-005Non-contact radar level sensor that reads through dust, steam and foam, for silos, bins, chests, sumps, oil tanks and dust-collector hoppers.0.3–12 m±2 mm typ.8° beamSpecs and uses
Process, rooms & cold chain

Pipe pressure sensor, 0–16 bar

CGUV-PRES-MILE-001Gauge pressure on hydraulic, chilled-water and process lines. The trend shows pump, loop and press hydraulic problems as they develop.0–16 bar (232 psi)±0.5% FSIP65Specs and uses
Process, rooms & cold chain

Differential pressure, rooms & filters

CGUV-PRES-SYNE-001Low-range wireless differential-pressure sensor for filter banks, collector bags, booths, coils and rooms, with temperature and humidity on board. A rapid change in pressure says more than the absolute value.DifferentialFilters · bags · rooms+ temperature & RHSpecs and uses
Process, rooms & cold chain

Tilt & position sensor

CGUV-STRUC-MILE-001Three-axis tilt sensor reporting angle and movement on dock levelers, extendable conveyors, lift tables, hoists, crane booms, dock gates and rack uprights.±90° range±1°IP67Specs and uses
Process, rooms & cold chain

Food-safety temperature, 2-channel

CGUV-TEMP-DRAG-009Two Class A PT100 probes on one food-grade transmitter for chill tanks, coolers, blast freezers, cold rooms and cook steps. Every reading is time-stamped.2 channels−40 to 260 °C±0.5 °C (0–80 °C)Specs and uses
Process, rooms & cold chain

Ultra-low PT100 probe, −196 °C

CGUV-TEMP-DRAG-012Two-channel transmitter with cryogenic-rated braided-metal probes for blast freezers, −40 rooms, and CO₂ or LN₂ chilling.−196 to 150 °C2 channelsClass A PT100Specs and uses
Process, rooms & cold chain

Magnet-mount temperature & humidity, IP67

CGUV-TEMP-MILE-003Magnet-mount temperature and humidity sensor for cabinets, racks and cold-room walls, used where condensation, dew point or heat is the concern: electrical rooms, RTE rooms, paint booths and docks.±0.2 °C · ±2% RHMagnet mountIP67 · food-grade housingSpecs and uses
Process, rooms & cold chain

Door contact, IP67

CGUV-DOOR-MILE-001Magnetic door contact with temperature and humidity sensing, rated for freezer and dock doors. It records how long each door is open, alongside the room temperature.Open / close+ temperature & RHIP67Specs and uses
Environment & water

Multi-parameter indoor air monitor

CGUV-IAQ-MILE-006CO₂, TVOC, PM2.5, temperature and humidity on one wall-mounted unit with an E-ink display. Trends by room and shift help EHS decide where to sample; the unit does not replace exposure sampling.CO₂ · TVOC · PM2.5Temperature & RHE-ink displaySpecs and uses
Environment & water

Particulate monitor, PM1 to PM10

CGUV-IAQ-DECL-002Optical particulate sensor reporting four size fractions, with temperature, humidity and barometric pressure, in an outdoor-rated enclosure for fence lines, dryer-stack areas, blast bays and mill rooms.PM1 · PM2.5 · PM4 · PM10+ temperature · RH · baroOutdoor ratedSpecs and uses
Environment & water

Sound level sensor

CGUV-SOUND-MILE-001Fixed sound-level sensor, 30–120 dBA with A or C weighting, reporting SPL, Leq and Lmax. It maps noise by work area and records when a process change raised levels.30–120 dBAA / C weightingSPL · Leq · LmaxSpecs and uses
Environment & water

Weather station, 11 parameters

CGUV-WTHR-DECL-002Wind speed and direction, rainfall, solar radiation, lightning, temperature, humidity and barometric pressure on one mast, recording wind direction for odor complaints and conditions for outdoor coating work.Wind · rain · solarLightning · temp · RH · baroIP67Specs and uses
Environment & water

Zone leak detector

CGUV-LEAK-MILE-003Leak-detection cable senses water anywhere along its length, and the node also reports temperature and humidity. For mechanical rooms, under chillers, at sprinkler risers and in switchgear rooms.3 m ropeIP6710-yr batterySpecs and uses
Environment & water

Spot leak detector

CGUV-LEAK-MILE-002Point probe on a 1.5 m lead for a single location, such as a drain pan, a defrost drain, a roof-drain pit or the area under a rooftop unit.Point probe1.5 m leadIP67Specs and uses
Environment & water

Water-quality converter

CGUV-WATR-DRAG-001Connects up to three RS485 probes to the dashboard for pH, ORP, conductivity, dissolved oxygen, turbidity, residual chlorine or temperature. For treated water, CIP final rinse and effluent.pH · ORP · chlorineConductivity · DO · turbidityUp to 3 probesSpecs and uses

Not sure which sensors you need?

Start from the problem, not the part number. The planner suggests a gateway and monitoring points for your facility, and a Cognituv engineer confirms them.

Plan your system