Water treatment · Cooling towers

Cleaner tower water, with less chemistry.

Cooling towers are warm, wet and open to the air, which suits biofilm and Legionella. Cognituv adds UV-C to the recirculating water and logs water quality in Cognituv Connect.

Two rooftop cooling tower fans with a plume of vapour, office towers behind, in Lower Manhattan

The problem

What facility teams tell us.

  • Biofilm costs heat transfer

    Fouled fill, basins and condenser tubes lower efficiency and raise energy use.

  • Legionella risk is managed by standard

    ASHRAE Standard 188 and many local codes call for a water management program for cooling towers.

  • Chemical programs keep growing

    Biocides, scale and corrosion inhibitors, plus the labor and logs to manage them.

  • Water costs money too

    Every gallon of blowdown is treated water going down the drain.

Where Cognituv fits

What we’d install, and where.

COOLING TOWER · THE RECIRCULATING LOOP Cooling tower Pump Chiller condenserMakeupwaterBlowdown 1In-line UV-C 2Basin UV-C 3Conductivity · pH · ORP4Cognituv Connect THE RECIRCULATING LOOP Cooling tower Pump Chiller condenser 1 2 34Cognituv Connect1In-line UV-C2Basin UV-C3Conductivity · pH · ORP

Facility types

The tower and the plant it serves.

What we look at first, where Cognituv fits and what you get from each item, the systems we usually find and the codes and standards to check. Codes and standards are listed for reference: a listing isn’t a compliance finding, and doesn’t mean any product, Cognituv’s included, is certified to one.

  • Cooling tower and central plant

    Open and closed-circuit towers and the condenser-water and chilled-water plant they serve.

    Includes: Open-circuit cooling tower · Closed-circuit cooling tower · Central chilled-water plant

    We look at
    • Biofilm in basins and fill
    • Water quality between tests
    • A record for your water management program

    Where Cognituv fits and what you get

    Typical systems
    Cooling towers · Condenser-water loop · Chillers

    Book an assessment for this facility

Identify · Apply · Verify™

What happens after you call.

  1. Identify

    Conductivity, pH and ORP sensors set a baseline alongside your current treatment logs.

  2. Apply

    In-line UV-C sized to the recirculation flow, or submersible UV-C in the basin.

  3. Verify

    Water quality and UV-C status in Cognituv Connect, ready for your water management program.

Where we work: Commercial HVAC towers, Data center cooling, Industrial process cooling, Hospital and campus central plants, Food and beverage plants and Power and utilities.

Codes and standards

Codes and standards to check.

The list comes from Cognituv’s facility and code library, reviewed September 2026. Publication isn’t adoption: whether a document applies, and which edition, depends on your jurisdiction, its amendments and your project, and the authority having jurisdiction decides. A listing isn’t a compliance finding for your facility, and doesn’t mean any product, Cognituv’s included, is certified to it.

See what the data says about your facility.

Start with a no-cost assessment: a call with an engineer and a written recommendation. When you want the data first, Cognituv Connect measures your own equipment, scoped and quoted for your site.

Prefer to talk? Call 1-888-580-8738